What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
Last Updated: 02.07.2025 03:43

[image of Common-mode choke]
First Sentence:
There are three different concepts here that are getting confused.
It also is a device that limits the change in current flow.
The bolt then partially travels down the line to your home.
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
What is your favourite true story to tell at a party?
A fuse is a non-resetable over current circuit protector.
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
He then describes Rainy Season and Lightning.
Aaron Rodgers says decision to sign with Steelers 'was best for my soul' - NFL.com
Edit 2024–10.
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.
But… the neutral is now “floating” because of the 1 ohm resistance.
The FDA Launches Its Generative-AI Tool, Elsa, Ahead of Schedule - Gizmodo
What does a fuse do?
It seems Mohan does not understand the difference between a comment and an Answer.
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
Xbox sale round-up June 3, 2025 - DLC - TrueAchievements
so, what happens?
nine
Can the fuse protect the electronic devices from lightning instead of a surge protector.
How can she get her mouth taped shut? She should not have freedom of speech.
This is 'the assistant's answer'
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
For 9 Days, Earth Was Sending Out Mysterious Signals. Now We Know What They Were. - Yahoo
Because the load is inductive, the current lags the voltage.(by a bit).
In schematic diagrams this is the symbol for a fuse:
One is “what exactly is in a ‘surge protector’ ? ”
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
What is lightning?
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
but this device (an Inductor) … impedes the rapid changes in the current.
At least they know the answer if they wanted it.
Is it because Trump is impulsive that he is never on time?
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
He then asserts :
Now when you have a certain ac resistance, then a current flows in a loop.
Ceres: The asteroid belt’s forgotten ocean world - Big Think
Upvotes:
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”
This one hit behind the barn.
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
At one ohm, the resistor has a maximum of 1 watt power.
the problem then depends on "how fast does the fuse operate?".
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
The third is lightning and “how it gets conducted into a home.”
[old diagram got deleted by accident]
but I think this circuit , shows a few more pieces.
P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
So, the voltage could go up to 500 volts, and the fuse will not open up.
This is the picture of an electronic coil of wire wound around a core of magnetic material.
These are simplified answers to the original question, and does not change anything I wrote above.
I post the exact comment here.
This device then solves the entire problem.
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
eight
One
(Dc diagram shown, AC is similar).
These devices are installed between the “hot” and “neutral” and protective ground.
The MOV will conduct when the voltage exceeds 50% of line voltage.
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
For this case there are devices called Metal oxide varistors (MOV).
2024–10–16 [ OO OLAOYE OYEBODE ]
A circuit breaker is similar, but is resettable.
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
This is where this question deviates from being a 'generic' question, and becomes more specific.
Barnstars:
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
2024–10–10[John johnson John Johnson ]
He then describes the function of a fuse.
what exactly is a ‘surge’ protector?
There are two important concepts here.
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
An AC voltage/ current source, and an ac inductive load.
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
But it can get overloaded, and no longer works.
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
2024–10–14 [Omar Gharbi Omar Gharbi ]
This is where the MOV conducts again, and dissipated the energy.
Here is a simplified AC power diagram.
a photo is worth a thousand words.
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
The other is “what does a “fuse” do?”